In Case of Fire- Use Elevators: Promoting Elevator-Assisted Evacuation

Monday, November 29th, 2010

For decades, plaques have been posted in elevator lobbies urging occupants to use the stairs during a fire. However, it took only 16 minutes on Sept. 11, 2001 to call into question almost a century of conventional wisdom. In those 16 minutes before the second tower at the World Trade Center was struck, nearly 3,000 occupants were able to evacuate to safety because they USED the elevators.

Last September marked the ninth anniversary of the World Trade Center Towers tragedy, prompting some to consider how far we have come in dealing with the aftermath of that attack and the proposed building code modifications that could potentially save lives during the evacuation of very tall buildings. One of those proposals, occupant-evacuation elevators as a secondary means of egress to stairs, has gained popularity (and a reference in the 2009 International Building Code), and have already been used in Freedom Tower (United Arab Emirates) and in modified form in such buildings as One Financial Center Shanghai and Stratosphere Tower (Las Vegas). Separately, the National Fire Protection Association (NFPA) added ‘Annex B’ to the NFPA 101 Life Saftey Code that defines how occupant evacuation elevators should be designed (which is a voluntary provision).

This marks the beginning of a growing trend.

Under the 2009 IBC, buildings taller than 75 feet are now required to have an elevator large enough to accommodate a stretcher. Buildings taller than 120 feet are required to have a special fire service elevator. Buildings taller than 420 feet need to have either a third stairwell or occupant evacuation elevators. Among the changes NFPA made : elevator lobbies need to be enclosed and located directly adjacent to an exit stairwell. Elevator lobbies may also grow in size to accommodate occupants who have gathered for an evacuation. Sprinklers are also prohibited from evacuation elevator machine rooms.

So, why were elevators banned from use a public egress in the first place?

Triangle Shirtwaist Factory

It was on March 25, 1911 that the most famous case of elevator evacuation failure occurred. The Triangle Shirtwaist Company was located on the top three floors (8th, 9th, and 10th) of the Asch building, a structure which remains standing today in New York City. A fire in a rag bin caused panic for the 500 sweatshop workers who occupied these floors. The elevator operations saved many lives by travelling three times up to the ninth floor for passengers, but they were eventually forced to give up when the rails of one of the two elevators buckled under the heat. Some victims pried the elevator doors open and jumped down the empty shaft in a desperate attempt to avoid the flames. The weight of these bodies made it impossible for the elevators to make another attempt. In total, 147 people died, many within the first 15 minutes of the start of the fire.

Elevator Operation and Fires

Today evacuation elevators can make it easier for mobility-impaired occupants to evacuate a building, and make it faster for those who need to use the stairwells to evacuate by speeding the overall flow, some experts say. However, elevator use is currently governed by the American Society of Mechanical Engineers (ASME) A17 Life Safety Code for Elevators and Escalators.The problem is that while NFPA and ICC have made code changes that begin to define evacuation elevators, ASME has not. Under ASME standards, once a fire has been detected elevators still operate under either Phase I or Phase II regulations.

Under Phase I operation, elevators that are 25 feet or more above the main floor return either to a designated landing area or an alternate area. Phase I operation is activated either manually by a special key, or automatically by a fire alarm initiating device. A sensor can detect smoke in the hoist-way, lobby or machine room and trigger Phase I. The goal is to remove the elevators form service so that building occupants DO NOT use elevators during a fire and become trapped.

Phase II operation is an override meant for firefighters after Phase I has been activated. Under Phase II operation, firefighters can use a key-switch to operate the elevator, provided the hoist-way is clear of smoke and the elevator has electricity.

Since 2004, ASME has been conducting a hazard analysis to determine how elevators might be safely used for evacuations. A related analysis is looking at whether fire fighters could use protected elevators to move close to a fire. Engineers from across the country are rethinking the traditional stairwell-centered approach to emergency egress from buildings and embracing a more holistic strategy that includes all aspects of building design and operation, as well as their impacts on occupant safety.

This December, the ASME is conducting a symposium on the use of elevators in fires and other emergencies, held in Orlando, Florida. Sponsors of this symposium include the National Institute of Standards and Technology (NIST), NFPA, and other related organizations. They are focusing on the progress of the ASME/a17 Task Group on the Use of Elevators by Firefights and Use of Elevators for Occupant Egress, as well as well as reviewing the code changes under development that affect elevator, building, and life safety codes. It appears that evacuation elevators are going to become another tool in making high-rises safer, if not an outright requirement in some cases. ASME, ICC and NFPA are all moving towards that same destination.

About the Author
Christopher E. Chwedyk, CSI, AIA is a licensed architect, Director and Chief Code Consultant of The Code Group at Burnham Nationwide in Chicago. He was previously the principal of Gage-Babcock and Associates; a firm specialized in fire protection engineering. With more than 33 years of experience in the architectural field, Mr. Chwedyk has performed numerous code compliance plan reviews for the City of Chicago and other municipalities. He has a BArch degree from UIC and a Masters of Project Management (MPM) from the Keller Graduate School of Management. An adjunct faculty member of Harper College, since 1998, Chris teaches courses on building codes and construction drawings.

Related Posts:

  • No Related Posts
"Burnham is a first-rate operation. I rely on them to coordinate many of the permit-related tasks that I am too busy to do myself. I draw on their knowledge on changing municipal requirements, proactive problem solving and would definitely recommend them to others."
Rich Neubauer,
McDonald's
"I've had great success with Burnham for permit expediting, and recently learned they offer code consulting. They are great in meetings and provide excellent reports supported by detailed research and experience. I will use them whenever I have code issues on a project."
Jeff Kennedy,
Centaur Construction
"I like Burnham because their response time is terrific. They're professional with a systematic approach and solid corporate infrastructure - and their web-based system shows me exactly what is happening with my permits at all times."
Tom McCloskey,
The Related Companies, L.P.
"Working with Burnham makes the best use of my resources. It would be too costly for me to have staff who know as much as they do about the permit process."
Mike Moravek,
The John Buck Company
"Burnham is always a vital part of our Project Team. Their level of service and professionalism far surpasses their competition. The first call I make when a new project comes in is to Burnham."
Gregg Navins,
OMARA Organization, Inc
"We have tried other permit services in the past but only Burnham delivers the level of detail, follow through and accountability necessary to be successful in today's complex permit acquisition arena."
Dave Morgan,
The Body Shop
"Speed and efficiency are paramount, we aren't looking for just another layer of project management. Burnham gets the process due to their strong knowledge of jurisdictional requirements, and excellent working relationships with municipal staffs."
Glenn D. Middleton,
Design Forum
"We have come to rely heavily on Burnham's expertise... they have developed a professional consulting practice that we are proud to be associated with."
Michael T Clune,
Clune Construction Company